Mini Compact Darkroom-UCC

一Product overview

As an alternative product of Gtem, UCC can be used in the field of pre-certification prediction and research and development.

As an alternative product of Gtem, UCC can be used in the field of pre-certification prediction and research and development. The walls and ceilings of the darkroom are fully covered with ferrite, and the 6m2 composite absorbing material is added to the back wall near Eut to ensure that the test frequency range of darkroom can be from 30MHz to 18GHz. The main advantage of the Mini compact darkroom is that the tester can walk inside, the test layout can have a cable fed to the peripherals, and a larger sample can be tested than the gtem compartment. UCC can be used to test the radiation emission and radiation immunity of the equipment in accordance with the iec/en 61000-4-3 standard requirements, in the meter distance. In addition, Din/iso 11452-2 and en 55025 (CISPR 25) are also suitable for testing automotive components. If necessary, UCC can also be used as a standard shielding room for conducting testing.


Because of its small external size, it can be placed in a normal sized laboratory or office.


The main advantage of the Mini compact darkroom is that testers can walk inside, test the layout with cables fed to peripherals, and test larger samples for distances of 1 meters.


Uniform Field Size



Technical Index

Overall dimensions (length x Width x height)

4280mm x 3080mm x 2550mm

Frequency range

30MHz~18GHz

Measuring distance

1m

Wave absorbing material laying

The long wall and the ceiling

F006 type ferrite absorbing material

The back wall near Eut

HF300-type composite wave absorbing material with central position 6㎡

Floor

Ferrite absorbing material between eut and antenna 2㎡

Radiation emission test

Predictive test

Radiation immunity Test

1-meter method of radiation immunity test conforming to Iec/en61000-4-3

0.5m x 0.5m


Maximum deviation

100% points in four points of measurement-0dB/+6dB